VT3 HIGH PRESSURE PUMP c/w gearbox 3/4"F206Bar13l

210 Bar (3050 PSI) Industrial PUMP and GEARBOX with 3/4" Shaft suitable for 3/4" horizontal shaft engines such as Loncin and HONDA GX160 . The pump is low revving which decreases wear. The flow rate of 13 litres per minute is suitable for most water mains supplies. The VT3 comes complete with unloader valve with 3/4F inlet and MSQ female outlet.
  • Note: the pressure must be set to unload at no more than 210 BAR (3050PSI). See safety note below:
  • Inlet fitting options include: MH12/12 or MH12/08 brass hose tails or B1.134 KCQ coupling. VIEW: COUPLINGS – LOW PRESSURE and COUPLINGS – QR LOW PRESSURE
  • Outlet fitting option: B14.9191 or B14.9191SS MSQ male to 3/8F coupling. VIEW: COUPLINGS – HIGH PRESSURE and COUPLINGS – QR HIGH PRESSURE
  • The VT3 pump and gearbox comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: C7.038BPKIT Pump priming valve kit ; E1.1013KIT PUMP SUCTION KIT (3m) ; PL500 V-TUF Pressure Lube (for pump top up)

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £491.39 incl tax £655.18 incl tax

    VT4 HIGH PRESSURE PUMP c/w gearbox 1"F250bar 15l

    250 Bar (3600 PSI) Industrial PUMP and GEARBOX with 1" Shaft suitable for 1" horizontal shaft engines such as Loncin and HONDA GX240 ; GX340 ; GX390 and YANMAR diesel engines. The pump is low revving which decreases wear. The flow rate is 15 litres per minute. The VT4 comes complete with unloader valve with 3/4F inlet and MSQ female outlet.
  • Note: the pressure must be set to unload at no more than 250 BAR (3600PSI). See safety note below:
  • Inlet fitting options include: MH12/12 or MH12/08 brass hose tails or B1.134 KCQ coupling. VIEW: COUPLINGS – LOW PRESSURE and COUPLINGS – QR LOW PRESSURE
  • Outlet fitting option: B14.9191 or B14.9191SS MSQ male to 3/8F coupling. VIEW: COUPLINGS – HIGH PRESSURE and COUPLINGS – QR HIGH PRESSURE
  • The VT4 pump and gearbox comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: C7.038BPKIT Pump priming valve kit ; E1.1013KIT PUMP SUCTION KIT (3m) ; PL500 V-TUF Pressure Lube (for pump top up)

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £635.29 incl tax £847.06 incl tax

    VT5 HIGH PRESSURE PUMP 3/4"F 190 Bar 13L

    190 Bar (2800 PSI) Industrial Pump with 3/4" Shaft suitable for 3/4" horizontal shaft engines such as Loncin and HONDA GX160 . The flow rate of 13 litres per minute is suitable for most water mains supplies. The VT5 comes complete with unloader valve with 3/4F inlet and MSQ female outlet.
  • Note: the pressure must be set to unload at no more than 190 BAR (2800PSI). See safety note below:
  • Inlet fitting options include: MH12/12 or MH12/08 brass hose tails or B1.134 KCQ coupling. VIEW: COUPLINGS – LOW PRESSURE and COUPLINGS – QR LOW PRESSURE
  • Outlet fitting option: B14.9191 or B14.9191SS MSQ male to 3/8F coupling. VIEW: COUPLINGS – HIGH PRESSURE and COUPLINGS – QR HIGH PRESSURE
  • The VT5 pump comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: C7.038BPKIT Pump priming valve kit ; E1.1012KIT PUMP SUCTION KIT (2m) ; PL500 V-TUF Pressure Lube (for pump top up)

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £357.22 incl tax £476.28 incl tax

    VT6 HIGH PRESSURE PUMP 1"F 206 Bar 15L

    V-TUF VT6 206 Bar (3030 PSI) Industrial Pump with 1" Shaft suitable for 1" horizontal shaft engines such as Loncin and HONDA GX240 ; GX340 ; GX390 and YANMAR diesel engines. The flow rate is 15 litres per minute. The VT6 comes complete with unloader valve with 3/4F inlet and MSQ female outlet.
  • Note: the pressure must be set to unload at no more than 206 BAR (3030PSI). See safety note below:
  • Inlet fitting options include: MH12/12 or MH12/08 brass hose tails or B1.134 KCQ coupling. VIEW: COUPLINGS – LOW PRESSURE and COUPLINGS – QR LOW PRESSURE
  • Outlet fitting option: B14.9191 or B14.9191SS MSQ male to 3/8F coupling. VIEW: COUPLINGS – HIGH PRESSURE and COUPLINGS – QR HIGH PRESSURE
  • The VT6 pump comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: C7.038BPKIT Pump priming valve kit ; E1.1013KIT PUMP SUCTION KIT (3m) ; PL500 V-TUF Pressure Lube (for pump top up)

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £367.67 incl tax £490.22 incl tax

    GEARBOX - FOR UP TO 18HP ENGINES, 1" SHAFT

    V-TUF RL400 REDUCTION GEARBOX for 1" horizontal shaft engines and pumps with 24mm shafts with 4 x 8mm bolt hole mount and 61mm between centres.
  • 1:2.24 reduction.
  • Suited to pumps: XHDM300 ; XHDM350; XHDM400, XHDM450; WS201.
  • Suited to engines: GX240QX ; GX390QX ; VLCP15 ; VLCD07 ; VLCD15 .
  • Recommended oil: PRESSURE LUBE PL500
  • £340.18 incl tax

    PUMP & MOTOR - 12L/min @ 100Bar (1500psi) 240v TS

    12L/min 100BAR LOW-REV HEAVY DUTY 170 bar rated Pump & Motor 240V - TSS - MH.243 + XHDM151 + C0.063 + I2.016 + I2.110 + (M8x25) x 4 + I3.325 x5
    £1,341.46 incl tax

    PUMP XHDM151 - 12L @ 170BAR, 1450RPM, MALE SHAFT

    V-TUF XHDM151 HIGH PRESSURE PUMP 170 Bar (2500 PSI); 12 litres per minute, Industrial Pump with 24mm MALE Shaft suitable for electric hollow shaft motors such as the MH.243 to run with a 05 jet or MH.4155 to run with a smaller jet for at pressures closer to 170 Bar . The flow rate of 12 litres per minute is suitable for most water mains supplies. The V-TUF XHDM151 comes without unloader valve. This pump MUST be fitted with an unloader valve KITS such as: C0.081KITRT or VTPS7007 (see IMPORTANT safety notice below).
  • 2 x Inlet 1/2F bsp ports – one ½F bsp port is supplied with a blanking plug
  • 2 x Outlet 3/8F bsp ports - one ½F bsp port is supplied with a blanking plug
  • The XHDM151 pump comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: PL500 V-TUF Pressure Lube (for pump top up)
  • Note: the pressure must be set to unload at no more than 170 BAR (2500PSI). See safety note below:

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £436.42 incl tax

    PUMP XHDM161 - 15L @ 160BAR, 1450RPM, MALE SHAFT

    V-TUF XHDM161 HIGH PRESSURE PUMP 160 Bar (2350 PSI); 15 litres per minute, Industrial Pump with 24mm MALE Shaft suitable for electric hollow shaft motors such as the MH.243 to run with a 07 jet or MH.4155 to run with a smaller jet for at pressures closer to 160 Bar (ALWAYS MAKE SURE the motor is running at least 15% within its maximum amperage). The flow rate of 15 litres per minute is higher than most water mains supplies. The V-TUF XHDM161 comes without unloader valve. This pump MUST be fitted with an unloader valve KITS such as: C0.081KITRT or VTPS7007 (see IMPORTANT safety notice below).
  • 2 x Inlet 1/2F bsp ports – one ½F bsp port is supplied with a blanking plug
  • 2 x Outlet 3/8F bsp ports - one ½F bsp port is supplied with a blanking plug
  • The XHDM161 pump comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: PL500 V-TUF Pressure Lube (for pump top up)
  • Note: the pressure must be set to unload at no more than 160 BAR (2350PSI). See safety note below:

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £436.42 incl tax

    PUMP XHDM300 - 12 L @ 160 BAR 1400 RPM, MALE SHAFT

    V-TUF XHDM300 HIGH PRESSURE PUMP 160 Bar (2350 PSI); 12 litres per minute, Industrial Pump with 24mm MALE Shaft suitable for electric hollow shaft motors such as the MH.243 to run with a 05 jet or MH.4155 to run with a smaller jet for at pressures closer to 170 Bar . The flow rate of 12 litres per minute is suitable for most water mains supplies. The V-TUF XHDM300 comes without unloader valve. This pump MUST be fitted with an unloader valve KITS such as: C0.081KITRT or VTPS7007 (see IMPORTANT safety notice below).
  • 2 x Inlet 1/2F bsp ports – one ½F bsp port is supplied with a blanking plug
  • 2 x Outlet 3/8F bsp ports - one ½F bsp port is supplied with a blanking plug
  • The XHDM300 pump comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: PL500 V-TUF Pressure Lube (for pump top up)
  • Note: the pressure must be set to unload at no more than 160 BAR (2350PSI). See safety note below:

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £787.78 incl tax

    PUMP XHDM350 - 15L @ 150 BAR 1400RPM, MALE SHAFT

    V-TUF XHDM350 HIGH PRESSURE PUMP 150 Bar (2200 PSI); 15 litres per minute, Industrial Pump with 24mm MALE Shaft suitable for electric hollow shaft motors such as the MH.243 to run with a 07 jet or MH.4155 to run with a smaller jet for at pressures closer to 150 Bar . The flow rate of 15 litres per minute is suitable for most water mains supplies. The V-TUF XHDM350 comes without unloader valve. This pump MUST be fitted with an unloader valve KITS such as: C0.081KITRT or VTPS7007 (see IMPORTANT safety notice below).
  • 2 x Inlet 1/2F bsp ports – one ½F bsp port is supplied with a blanking plug
  • 2 x Outlet 3/8F bsp ports - one ½F bsp port is supplied with a blanking plug
  • The XHDM350 pump comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: PL500 V-TUF Pressure Lube (for pump top up)
  • Note: the pressure must be set to unload at no more than 150 BAR (2200PSI). See safety note below:

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £787.78 incl tax

    PUMP XHDM400 - 15L @ 200 BAR, 1400 RPM, MALE SHAFT

    V-TUF XHDM400 HIGH PRESSURE PUMP 200 Bar (3000 PSI); 15 litres per minute, Industrial Pump. (Replaces the - RK15.20H ) It has a 24mm MALE Shaft suitable for electric hollow shaft motors such as the commonly used MH.4175 to run with an 05 jet at 200 Bar (ALWAYS MAKE SURE the motor is running at least 15% within its maximum amperage). The flow rate of 15 litres per minute is higher than most water mains supplies so drawing from a tank is recommended. The V-TUF XHDM400 comes without unloader valve. This pump MUST be fitted with an unloader valve KITS such as: C0.081KITRT or VTPS7007 (see IMPORTANT safety notice below).
  • 2 x Inlet 1/2F bsp ports – one ½F bsp port is supplied with a blanking plug
  • 2 x Outlet 3/8F bsp ports - one ½F bsp port is supplied with a blanking plug
  • The XHDM400 pump comes lubricated complete with V-TUF PRESSURE LUBE PL500.
  • OPTIONAL EXTRAS: PL500 V-TUF Pressure Lube (for pump top up)
  • Note: the pressure must be set to unload at no more than 200 BAR (3000PSI). See safety note below:

    IMPORTANT SAFETY NOTE: BEFORE powering the system: 1. the unloader valve MUST be set at MINIMUM pressure; 2. The bypass port MUST be open; 3. Then set the unloader to the required pressure (which MUST be LESS than the maximum unloader pressure of the unloader valve AND LESS than the maximum pressure of your equipment); 4. Set the locking nuts so this pressure (the running pressure and the lock line pressure) cannot be exceeded.
  • CAUTION: This is high pressure equipment and if the above safety and set up rules are not followed, serious damage to equipment and injury to humans can occur. The caps and joints can be blown clean out of their threads which cause dangerous projectiles. Please be free to ring 01522 787978 if you need any assistance.
  • £904.79 incl tax